Aluminum High Pressure Blower

A-HP 250/40

Flow rate up to 90 m³/min and 13.650 Pa. Minimal wear, direct drive with offset Frequency Converter (FU) or mounted (FUK). Housing consists of aluminum cast. Impeller and housing are optimised and perfectly matched. Maximum performance from such a compact design.

Characteristic curves

Performance data

Efficiency class

Volume flow

Total pressure difference

Voltage

Frequency

Current consumption

Performance

Fan speed

Weight

-

m³/min

Pa

V

Hz

A

kW

min-1

kg

A-HP 250/40-140/3,0

-

15,2

8500

400

140

6,3

3,0

8275

29

A-HP 250/40-140/4,0

-

26,0

8580

400

140

8,5

4,0

8310

33

A-HP 250/40-140/5,5

-

39,8

8580

400

140

9,5

5,5

8300

33

Characteristic curves

Performance data

Efficiency class

Volume flow

Total pressure difference

Voltage

Frequency

Current consumption

Performance

Fan speed

Weight

-

m³/min

Pa

V

Hz

A

kW

min-1

kg

A-HP 250/40-140/3,0

-

15,2

8500

400

140

6,3

3,0

8275

35

A-HP 250/40-140/4,0

-

26,0

8580

400

140

8,5

4,0

8310

39

A-HP 250/40-140/5,5

-

39,8

8580

400

140

9,5

5,5

8300

43

Technical drawings

Downloads

Instruction manual A-HP (de, en)

Instruction manual PDF 2 MB

Instruction manual A-HP (zh)

Instruction manual PDF 3 MB

Katalog_A-HP_DE_EN.pdf

Catalogue PDF 6 MB

Accessories

A-HP 250/40 Enquire

Our experts are ready to assist you.

Enquire now

About our products

A peak into production

Take a peak at our Waghäusel and Chorzów production locations and learn more about the manufacture of our fans and side channel blowers.

learn more

Applications

Elektror airsystems offers solutions for any application type and is therefore represented in numerous industries.

learn more

Downloads

Looking for operating instructions, catalogues or dimensional drawings? You will find all the downloads here.

to the downloads